Search results for "Gas detector"
showing 10 items of 30 documents
NEXT-100 Technical Design Report (TDR). Executive summary
2012
[EN] In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (ßß0v) in 136XE at the Laboratorio Subterráneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The readout pla…
Signal Characteristics of a Resistive-Strip Micromegas Detector with an Integrated Two-Dimensional Readout
2014
In recent years, micropattern gaseous detectors, which comprise a two-dimensional readout structure within one PCB layer, received significant attention in the development of precision and cost-effective tracking detectors in medium and high energy physics experiments. In this article, we present for the first time a systematic performance study of the signal characteristics of a resistive strip micromegas detector with a two-dimensional readout, based on test-beam and X-ray measurements. In particular, comparisons of the response of the two independent readout-layers regarding their signal shapes and signal reconstruction efficiencies are discussed.
Detection of lung cancer bio-markers in human breath using a micro-fabricated air analyzer
2015
International audience; The analysis of volatile organic compounds (VOCs) that are linked to lung cancer is a very promising way in medical diagnostics because it is non-invasive and potentially inexpensive. In that sense, a silicon micro-analytical platform consisting of a three-dimensional micro-preconcentrator coupled to a silicon spiral gas chromatographic micro-column was built. A metal oxide-based gas sensor acted as a miniaturized gas detector. This system allowed selective detection of VOCs at the sub-ppm level. The present study is focused first on the chromatographic air analyzer fabrication and second on the selection of an appropriate adsorbent. Various adsorbents such as activa…
Development and Study of a Micromegas Pad-Detector for High Rate Applications
2015
In this paper, the design and the performance of two prototype detectors based on Micromegas technology with a pad readout geometry is discussed. In addition, two alternative implementations of a spark-resistent protection layer on top of the readout pads have been tested to optimize the charge-up behavior of the detector under high rates. The prototype detectors consist of 500 pads with a size of 5x4 mm, each connected to one independent readout channel, and cover an active area of 10x10 cm. The design of these prototypes and its associated readout infrastructure was developed in such a way that it can be easily adapted for large-size detector concepts.
Construction of large-area micro-pattern gaseous detectors
2016
Particle physics experiments often comprise tracking detectors with areas of up to a few square meters. If a spatial resolution of the order of 100μm and high-rate capability are required, Micro Pattern Gaseous Detectors (MPGD) are a cost-effective solution. However, the construction of large-area MPGDs is challenging, since tight fabrication tolerances have to be met to guarantee a stable and homogeneous performance. A precision granite table and an automated 3-D positioning system with an attached laser sensor, both inside a laminar-flow cell, have therefore been set up in the PRISMA Detector Lab at Mainz. Currently, this infrastructure is used to produce drift panels for the upgrade of t…
Conceptual design of the International Axion Observatory (IAXO)
2014
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion helioscope, reaching sensitivity to axion-photon couplings down to a few $\times 10^{-12}$ GeV$^{-1}$ and thus probing a large fraction of the currently unexplored axion and ALP parameter space. IAXO will also be sensitive to solar axions produced by mechanisms mediated by the axion-electron coupling $g_{…
SiPM based tracking for detector calibration in NEXT
2015
197 páginas. Tesis Doctoral del Departamento de Física Atómica, Molecular y Nuclear de la Universidad de Valencia y del Instituto de Física Corpuscular (IFIC).
The NEXT experiment for neutrinoless double beta decay searches
2015
211 páginas. Tesis Doctoral del Departamento de Física Atómica, Molecular y Nuclear, de la Universidad de Valencia y del Instituto de Física Corpuscular (IFIC).
Chromatographic Air Analyzer Microsystem for the Selective and Sensitive Detection of Explosive-related Compounds
2014
Abstract The detection of explosives and explosive-related compounds is of major importance for the monitoring of explosive- contaminated sites. Current methods need to become cheaper and portable while maintaining a high sensitivity and selectivity level. In that sense, a silicon micro-analytical platform consisting of a three-dimensional micro-preconcentrator based on a hydrophobic zeolite, coupled to a silicon spiral micro-column was built. A chemical gas sensor acted as a miniaturized gas detector. This system allowed selective detection of orthonitrotoluene (ONT), an explosive-related compound at the sub-ppm level in the presence of toluene and moisture.
Development of a micro-analytical prototype for selective trace detection of orthonitrotoluene
2014
Abstract A silicon micro-analytical platform consisting of a micro-preconcentrator based on a hydrophobic zeolite, coupled to a silicon spiral micro-column was built. A chemical gas sensor acted as a miniaturized gas detector. This system allowed selective detection of orthonitrotoluene (ONT), an explosive-related compound at the sub-ppm level (365 ppb) in the presence of toluene and moisture.